LG Dryer — Error Code NP
No current is being sensed at the heater, usually a home wiring or supply issue.
ApplianceDB ranks 1 repair for this code, led by “Verify the power connection”. That top fix is a moderate-difficulty DIY job, involving the heater circuit. Severity is classified as stop failure — the appliance halts until the fault clears.
Ranked repair steps
1. Verify the power connection
Confirm the cord is secure in a grounded 240V outlet matching the rating plate, reset the breaker for ten seconds, and have an electrician verify the voltage if the code persists.
moderate · basis: manufacturer first
Provenance: facts re-derived from an official manufacturer listing — LG USA Support — Dryer Error Code List. Meanings and steps are original paraphrase; nothing is reproduced verbatim.